Quality Control

Our testing laboratory is equipped with modern testing equipment that meets Russian and global requirements and carries out mechanical and climatic tests, multiple and single impacts, linear acceleration, exposure to solar radiation, high humidity, as well as static and dynamic dust tests, atmospheric pressure, electric insulation strength in accordance with the field of certification.


List of types of tests conducted in the control and testing laboratory of JSC "PA “UOMP"

Types of tests for external factors effect
Designation of RD establishing test standards
The ranges of characteristics of the external factors reproduced by the measuring equipment
Mass-dimensional characteristics of the tested products,
kg, mm х mm х mm
1 High ambient temperature test
For periodic tests, the technical conditions for the products tested.

In the case of standard tests, test programs, GOSTs, OSTs.

In the preliminary testing of prototypes of products - the program - the methodology and the draft specifications.

In case of acceptance testing, the technical conditions.

Programs and techniques when working out prototypes of products.
Temperature effect from 0ºC to + 150ºС

500

2,850х600х400

2 Low ambient temperature test
Temperature effect from 0ºC to -70ºС

500

–//–

3 Exposure to high humidity
Relative humidity from 10% to 98%

500

–//–

4 Temperature change test
Temperature effect from -70ºС to +150ºС

500

–//–

5 High pressure air (gas) test
Increased pressure up to 3 atm

2

130х130х450

6 Rapid change in pressure (take-off) test
Low pressure up to 30 mm Hg

200

850х600х400

7 Sand and dust tests
Air speed 1.0 m/s

200

500х300х300

8 Leak tests
Minimum flow of helium not more than 7х10-12 m х cPs

2

300х200х100

9 Tests for the effects of atmospheric precipitation (rain)
Rain intensity 5 mm

500

2,850х400х400

10 Vibration tests
Vibration effect in the frequency range from 5 Hz to 2000 Hz with acceleration from 3m / s2

500

2,850х600х600

11 Impact tests

Impact from 20 m/s2 to 150 m/s2 for a duration of 15 ms to 20 ms
Maximum acceleration 1,000gDuration from 2 ms to 35 ms.
Duration from 2 ms to 35 ms. (half-sine) 10 ms to 70 ms trapezoidal

500

2,850х600х600

12 Linear acceleration resistance tests
Linear overloads from 10 m/s2 to 500 m/s2

200

850х600х400

13 Dielectric strength of insulation
Operating voltage range up to 10 kW AC and DC

30

600х400х300